Snapshot generated Nov 10, 2026, 14:25 ET  ·  source: SAM.gov + USAspending live ETL
← All opportunities
Active Award Notice · VETERANS AFFAIRS, DEPARTMENT OF › VETERANS AFFAIRS, DEPARTMENT OF › TECHNOLOGY ACQUISITION CENTER NJ (36C10B)

DA10--NEW TO -Enterprise QA Software System & Repository (VA-26-00052553)

Solicitation 36C10B26Q0804 · Notice ID ee29fedfb0524fc3a34ce39b2c2631d0

General Information

Classification

Notice Type Award Notice
Status Active
Solicitation Number 36C10B26Q0804
Notice ID ee29fedfb0524fc3a34ce39b2c2631d0
Posted Sep 30, 2026, 9:45 AM ET
Last Modified Sep 30, 2026, 9:45 AM ET
Archive Date Jan 7, 2027
NAICS
541519 · Other Computer Related Services
PSC
DA10 · IT AND TELECOM - BUSINESS APPLICATION/APPLICATION DEVELOPMENT SOFTWARE AS A SERVICE
DA - IT AND TELECOM - APPLICATIONS
Set-aside Small Business
Total Small Business Set-Aside (FAR 19.5)

Organization

Department VETERANS AFFAIRS, DEPARTMENT OF · 3600
Sub-Agency VETERANS AFFAIRS, DEPARTMENT OF · 3600
Office TECHNOLOGY ACQUISITION CENTER NJ (36C10B) · 36C10B

Point of Contact

Candice Mazzetta
Contract Specialist
primary
848-377-5176

Description

On September 29, 2026, the Department of Veterans Affairs (VA) Technology Acquisitions Center (TAC) in support of the Veterans Health Administration (VHA), National Radiation Oncology Program, awarded a Firm Fixed Price contract to Radformation, Inc., 261 Madison Avenue New York, NY 10016, for an Enterprise-wide Radiotherapy Technical Quality Assurance (QA) System and Repository. The contract will provide a Commercial Off-The-Shelf (COTS) online, vendor-agnostic, enterprise-wide Software as a Service (SaaS) Radiotherapy Quality Assurance (QA) solution that standardizes, automates, and centralizes treatment delivery device QA data acquisition, analysis, and reporting across all VA Radiation Oncology Centers. The solution will streamline quality monitoring of linear accelerators (linacs) and other radiation treatment devices, including, but not limited to, brachytherapy and other non-linac teletherapy systems; imaging systems, including diagnostic systems such as computed tomography (CT) and magnetic resonance imaging (MRI) devices, as well as on-board imaging and other radiotherapy positioning verification and monitoring systems; and QA devices across diverse vendors. The solution shall comply with the applicable requirements of the American Association of Physicists in Medicine (AAPM) Task Group (TG)-142, TG-51, TG-198, as well as Medical Physics Practice Guidelines (MPPG) and Protocols. The period of performance shall consist of a 12-month base period, with four 12-month option periods.